HYLX neutral current sink

Short Description:

There are 3, 6, 9, and 12 harmonics in zero-sequence harmonics in the neutral line. Excessive current in the neutral line will easily cause the circuit breaker to trip, and the heating of the neutral line will seriously cause fire safety hazards.

More

Product Detail

Product Tags

product description

HYLX series zero line current absorber generates equal and opposite magnetic flux inside the device after detection and calculation to offset, thereby filtering out the third harmonic current, eliminating the zero line current, and effectively solving the problem caused by excessive zero line current of the equipment. Equipment failure and safety hazards.
Zero-sequence harmonic hazard description

img-1

 

Application range

●Office buildings, office buildings: a large number of office automation equipment, computers, printers, copiers, UPS power supplies, energy-saving lamps, billboards;
●Scientific research building: a large number of information equipment, UPS power supply, scientific instruments, energy-saving lamps;
●Communication room: a large number of information processing equipment, servers, UPS power supply, communication equipment;
●Traffic command center: a large number of information processing equipment, servers, UPS power supply, communication equipment;
●Shopping malls: energy-saving lamps, billboards, large-size LED screens;
●Hospital: medical equipment, UPS power supply, energy-saving lamps;
●Financial institutions: a large number of office automation equipment, information and communication equipment, servers, printers, copiers, UPS power supplies, energy-saving lamps;
●Hotels: energy-saving lamps, computers, billboards;

Technical Parameters

Features
●Automatic maintenance is simple;
●The warranty is 3 years, and the service life is as long as 20 years;
●Effectively filter out the 3rd harmonic, thereby reducing the neutral current, the effect can reach 65~95%;
●Small size, compact structure, indoor/outdoor options;
●No other power electronic devices are needed, the failure rate is zero and the reliability is high;
●It is equipped with an independent circuit breaker, and the fault will automatically exit without affecting the operation of the system;
●Parallel access system, zero resonance;
●Only filter out harmonics, do not change the original three-phase voltage, do not increase the neutral line voltage;
●Reduce cable heating, reduce cable use cross-sectional area, and the saving rate can reach more than 20%;
●Complies with the national standard “Code for Grounding Design of Industrial and Civil Power Installations” (GBJ65-83),
●Personal safety: zero voltage after installation of the neutral line current absorber, no danger for people touching the neutral line.