Harmonic Control Series

  • HYFC-ZP series intermediate frequency furnace passive filter energy saving compensation device

    HYFC-ZP series intermediate frequency furnace passive filter energy saving compensation device

    The intermediate frequency furnace is a nonlinear load. It injects harmonic current into the grid during operation, and generates harmonic voltage on the impedance of the grid, resulting in voltage distortion of the grid, affecting the quality of power supply and the safety of equipment operation.

  • Special filter compensation device for HYFCKRL series submerged arc furnace

    Special filter compensation device for HYFCKRL series submerged arc furnace

    Submerged arc furnace is also called electric arc furnace or resistance electric furnace. One end of the electrode is embedded in the material layer, forming an arc in the material layer and heating the material by its own resistance. It is often used for smelting alloys, smelting nickel matte, matte copper, and producing calcium carbide. It is mainly used for reducing smelting ores, carbonaceous reducing agents and solvents and other raw materials. It mainly produces ferroalloys such as ferrosilicon, ferromanganese, ferrochrome, ferrotungsten and silicon-manganese alloy, which are important industrial raw materials in the metallurgical industry and chemical raw materials such as calcium carbide. Its working feature is to use carbon or magnesia refractory materials as the furnace lining, and use self-cultivating graphite electrodes. The electrode is inserted into the charge for submerged arc operation, using the energy and current of the arc to smelt metal through the energy generated by the charge and resistance of the charge, feeding successively, intermittently tapping iron slag, and continuously operating an industrial electric furnace. At the same time, calcium carbide furnaces and yellow phosphorus furnaces can also be attributed to submerged arc furnaces due to the same use conditions.

  • HYLX neutral current sink

    HYLX neutral current sink

    There are 3, 6, 9, and 12 harmonics in zero-sequence harmonics in the neutral line. Excessive current in the neutral line will easily cause the circuit breaker to trip, and the heating of the neutral line will seriously cause fire safety hazards.

  • HYFC series low voltage static passive filter compensation device

    HYFC series low voltage static passive filter compensation device

    HYFC type power filter compensation device is an economical tuning filter and compensation equipment, which is composed of professionally designed and manufactured filter reactors, filter capacitors, filter resistors, contactors, circuit breakers and other components to form a specific frequency tuning filter branch. Under the resonant frequency, XCn=XLn can form an approximate short-circuit circuit for the relevant harmonics, effectively absorb and filter the characteristic harmonics of the harmonic source, compensate reactive power, improve the power factor and eliminate the harmonic pollution of the power grid. The device adopts comprehensive protection control, easy to use. The tuning filter branch adopts computer simulation design, analyzes and calculates according to the actual situation of users, so that the operation of the device can achieve the best effect, the use of electrical equipment can maximize the potential, and win more economic benefits for users.

  • HYTSF series low voltage dynamic filter compensation device

    HYTSF series low voltage dynamic filter compensation device

    With the improvement of the country’s industrialization level, all walks of life have higher and higher requirements for the quality of the power grid. At the same time, industrial automation uses a large number of rectifiers, frequency converters, intermediate frequency furnaces and automatic welding equipment to generate a large number of harmonics, which makes the voltage and current in the system. Waveform distortion causes the quality of the power grid to deteriorate, and the harm of harmonics has become the main public hazard of the power grid. In order to filter out the harmonics on the power supply system, using a harmonic filter reactive power compensation device is one of the best methods.

  • HYFC-BP series inverter dedicated passive filter device

    HYFC-BP series inverter dedicated passive filter device

    The filter is developed and produced by Hongyan Company. It adopts Fourier analysis broadband filter technology, uses digital monitoring to store and record various electrical data, fully realizes automatic and intelligent switching filter circuit, and effectively filters out 5th, 7th, 11th harmonics. Purify the power transmission and distribution network, prevent electromagnetic interference, and improve the power factor of the inverter at the same time, which has a significant energy-saving effect.

  • Passive filter compensation device for HYFC-ZJ series rolling mill

    Passive filter compensation device for HYFC-ZJ series rolling mill

    The harmonics generated in cold rolling, hot rolling, aluminum oxidation, and electrophoresis production are very serious. Under a large number of harmonics, the cable (motor) insulation attenuates rapidly, the loss increases, the output efficiency of the motor decreases, and the capacity of the transformer decreases; when the input power is caused by the user When the waveform distortion caused by harmonics exceeds the national limit value, the electricity consumption rate increases and the power supply may be terminated. Therefore, no matter from the perspective of equipment, the impact on power supply, or the interests of users themselves, the harmonics of electricity consumption should be handled well and the power factor of electricity consumption should be improved.

  • HYFC series high voltage passive filter compensation device

    HYFC series high voltage passive filter compensation device

    Non-linear loads in industries such as steel, petrochemical, metallurgy, coal, and printing and dyeing generate a large number of harmonics during work, and the power factor is low, causing serious pollution to the power system and affecting the quality of power supply. The high-voltage passive filter compensation complete set is mainly composed of filter capacitors, filter reactors and high-pass resistors to form a single-tuned or high-pass filter channel, which has a good filtering effect on specific harmonics and harmonics above specific orders. At the same time, reactive power compensation is performed on the system to improve the power factor of the system, improve the voltage stability of the system, and ensure the safety and reliability of the power supply system. Because of its economy and practicality, simple structure, reliable operation and convenient maintenance, it has been widely used in high-voltage systems.

  • HYMSVC series high voltage reactive power dynamic filter compensation device

    HYMSVC series high voltage reactive power dynamic filter compensation device

    The three major indicators of power system voltage, reactive power and harmonics are crucial to improving the economic benefits of the entire network and improving the quality of power supply. At present, the adjustment methods of traditional group switching capacitor compensation devices and fixed capacitor bank compensation devices in China are discrete, and cannot achieve ideal compensation effects; at the same time, the inrush current and overvoltage caused by switching capacitor banks have a negative It will cause harm in itself; existing dynamic reactive power compensation devices, such as phase-controlled reactors (TCR type SVC), are not only expensive, but also have the disadvantages of large floor area, complex structure, and large maintenance. Magnetically controlled reactor type dynamic reactive power compensation device (referred to as MCR type SVC), the device has significant advantages such as small output harmonic content, low power consumption, maintenance-free, simple structure, high reliability, low price, and small footprint It is the ideal dynamic reactive power compensation device in China at present.